Back to list

Oranier Heiztechnik GmbH Neta

Oranier Heiztechnik GmbH

Wood
Rated output
8kW
+1.4 kW vs. avg
Exhaust temperature
142°C
−133.9 °C vs. avg
Exhaust mass flow
5.9g/s
−0.7 g/s vs. avg
Connection diameter
80mm
−65.4 mm vs. avg

Condensation risk

Worst case (old uninsulated masonry chimney, U≈2.5 W/m²K, −10 °C): inner wall drops below dew point 55 °C from approx. 6 m height. A modern insulated stainless-steel chimney avoids this.

Diagrams

Condensation risk

Inner chimney wall temperature over height — modern insulated (U≈0.6) vs. old masonry (U≈2.5). Condensation occurs when the inner wall drops below the acid or water dew point.

Draft balance

Natural draft vs. required draft pressure — shows from which height enough draft develops.

Flue gas core vs. inner wall

Gas core temperature (dashed) and inner wall temperature (solid) at winter -15 °C — the inner wall reaches the dew point much earlier and decides whether condensation occurs.

Metric comparison

Appliance metrics relative to the average of all appliances using the same fuel (100% = average).

Emissions & ratings

Compliance against the major European emission standards.

EU Ecodesign
compliant
DE BImSchV
stage 2
Austria
compliant
Switzerland
compliant
Denmark
compliant
France (Flamme verte)
7 stars
Italy
4 stars

Certifications

2. Stufe BimSchVCEA+Art. 15 a B-VG (Österreich)EN 14785DIN EN 16510

Operation & compatibility

Operating modes and approvals declared by the manufacturer.

Continuous burningNo
Multi-flue suitableNo
Room-air independentNo
Central-heating connectionNo
DIBt approvalNo
BAFA-eligibleNo
CirculationLuftgeführt
Flue connectionoben, hinten
External combustion air50 mm

Fuels

Pellets

Geometry & design

Physical dimensions and outer materials.

Dimensions H×W×D
1063 × 510 × 524 mm
Weight
125 kg
Base shape
eckig
Cladding
Stahl
Colour
schwarz, weiß, rot
Efficiency
87 %
Heating area
83 m²
Pellet hopper capacity
24 kg
Burn duration per fill
12 h
Fuel consumption (min)
0,6 kg/h

Test certificate

Test report and identification numbers.

Standard
DIN EN 14785
Year
2021
Institute
Strojirensky Zkusebni Ustav s.p.
Report no.
30-15199/1/T
Article no.
7961

Data sources: schornstein

Technical parameters
Appliance
Oranier Heiztechnik GmbH Neta
Manufacturer
Oranier Heiztechnik GmbH
Fuel
Wood
Rated output
8 kW
Exhaust temperature
142 °C
Exhaust mass flow
5.9 g/s
CO₂ content
7 %
Operating pressure
12 Pa (overpressure)
Connection diameter
80 mm
Water dew point (approx.)
55 °C
Acid dew point (approx.)
70 °C