Back to list

Lotus Heating Systems A/S Jubilee 20

Lotus Heating Systems A/S

Wood
Rated output
4kW
−2.6 kW vs. avg
Exhaust temperature
302°C
+26.1 °C vs. avg
Exhaust mass flow
3.9g/s
−2.7 g/s vs. avg
Connection diameter
150mm
+4.6 mm vs. avg

Condensation risk

Worst case (old uninsulated masonry chimney, U≈2.5 W/m²K, −10 °C): inner wall drops below dew point 55 °C from approx. 5 m height. A modern insulated stainless-steel chimney avoids this.

Diagrams

Condensation risk

Inner chimney wall temperature over height — modern insulated (U≈0.6) vs. old masonry (U≈2.5). Condensation occurs when the inner wall drops below the acid or water dew point.

Draft balance

Natural draft vs. required draft pressure — shows from which height enough draft develops.

Flue gas core vs. inner wall

Gas core temperature (dashed) and inner wall temperature (solid) at winter -15 °C — the inner wall reaches the dew point much earlier and decides whether condensation occurs.

Metric comparison

Appliance metrics relative to the average of all appliances using the same fuel (100% = average).

Emissions & ratings

Compliance against the major European emission standards.

EU Ecodesign
compliant
DE BImSchV
stage 2
Austria
compliant
Switzerland
compliant
France (Flamme verte)
7 stars
Italy
3 stars

Certifications

CEA+NS 3058EN 13240DINplus15a B-VGBImSchV 2. Stufe

Operation & compatibility

Operating modes and approvals declared by the manufacturer.

Continuous burningNo
Multi-flue suitableYes
Room-air independentNo
Central-heating connectionNo
DIBt approvalNo
CirculationLuftgeführt
Flue connectionoben, hinten
External combustion air80 mm

Fuels

WoodCoal

Geometry & design

Physical dimensions and outer materials.

Dimensions H×W×D
985 × 491 × 301 mm
Viewing window H×W
375 × 305 mm
Weight
127 kg
Base shape
eckig
Cladding
Speckstein
Colour
schwarz
Efficiency
81 %
Heating area
80 m²
Max log length
30 cm
Viewing window H×W
Frontkamin: 1 Scheibe, Frontscheibe
Baking compartment
ohne Backfach

Test certificate

Test report and identification numbers.

Standard
EN 13240
Year
2021
Institute
RRF Rhein-Ruhr-Feuerstättenprüfstelle GmbH
Report no.
RRF - 40 21 5846
Article no.
10057

Data sources: schornstein

Technical parameters
Appliance
Lotus Heating Systems A/S Jubilee 20
Manufacturer
Lotus Heating Systems A/S
Fuel
Wood
Rated output
4 kW
Exhaust temperature
302 °C
Exhaust mass flow
3.9 g/s
CO₂ content
7 %
Operating pressure
12 Pa (overpressure)
Connection diameter
150 mm
Water dew point (approx.)
55 °C
Acid dew point (approx.)
70 °C