Back to list

Hark GmbH & Co. KG Hark 17

Hark GmbH & Co. KG

Wood
Rated output
7kW
+0.4 kW vs. avg
Exhaust temperature
340°C
+64.1 °C vs. avg
Exhaust mass flow
6.4g/s
−0.2 g/s vs. avg
Connection diameter
150mm
+4.6 mm vs. avg

Condensation risk

Worst case (old uninsulated masonry chimney, U≈2.5 W/m²K, −10 °C): inner wall drops below dew point 55 °C from approx. 8 m height. A modern insulated stainless-steel chimney avoids this.

Diagrams

Condensation risk

Inner chimney wall temperature over height — modern insulated (U≈0.6) vs. old masonry (U≈2.5). Condensation occurs when the inner wall drops below the acid or water dew point.

Draft balance

Natural draft vs. required draft pressure — shows from which height enough draft develops.

Flue gas core vs. inner wall

Gas core temperature (dashed) and inner wall temperature (solid) at winter -15 °C — the inner wall reaches the dew point much earlier and decides whether condensation occurs.

Metric comparison

Appliance metrics relative to the average of all appliances using the same fuel (100% = average).

Emissions & ratings

Compliance against the major European emission standards.

DE BImSchV
stage 2
Austria
compliant
Switzerland
compliant
Denmark
compliant
France (Flamme verte)
7 stars

Certifications

2. Stufe BimSchVCENS 3058Eco Design 2022DIN EN 13240Art. 15 a B-VG (Österreich)

Operation & compatibility

Operating modes and approvals declared by the manufacturer.

Continuous burningNo
Multi-flue suitableYes
Room-air independentNo
Central-heating connectionNo
DIBt approvalNo
CirculationLuftgeführt
Flue connectionoben, hinten
External combustion air80 mm

Fuels

WoodCoal

Geometry & design

Physical dimensions and outer materials.

Dimensions H×W×D
982 × 500 × 453 mm
Weight
108 kg
Base shape
eckig
Cladding
Stahl, Gusseisen
Colour
schwarz
Efficiency
78 %
Heating area
30 m²
Max log length
39 cm
Viewing window H×W
Panoramakamin: 3 Scheiben, dreiseitige-Kamine
Baking compartment
ohne Backfach

Test certificate

Test report and identification numbers.

Standard
DIN EN 13240
Year
2015
Institute
Feuerstättenprüfstelle Kahl GmbH
Report no.
FK 40 13 252
Article no.
50571

Data sources: schornstein

Technical parameters
Appliance
Hark GmbH & Co. KG Hark 17
Manufacturer
Hark GmbH & Co. KG
Fuel
Wood
Rated output
7 kW
Exhaust temperature
340 °C
Exhaust mass flow
6.4 g/s
CO₂ content
7 %
Operating pressure
12 Pa (overpressure)
Connection diameter
150 mm
Water dew point (approx.)
55 °C
Acid dew point (approx.)
70 °C