Back to list

Drooff Kaminöfen GmbH & Co. KG Livera 2 L (6 kW)

Drooff Kaminöfen GmbH & Co. KG

Wood
Rated output
6kW
−0.6 kW vs. avg
Exhaust temperature
321°C
+45.1 °C vs. avg
Exhaust mass flow
5.67g/s
−0.9 g/s vs. avg
Connection diameter
150mm
+4.6 mm vs. avg

Condensation risk

Worst case (old uninsulated masonry chimney, U≈2.5 W/m²K, −10 °C): inner wall drops below dew point 55 °C from approx. 7 m height. A modern insulated stainless-steel chimney avoids this.

Diagrams

Condensation risk

Inner chimney wall temperature over height — modern insulated (U≈0.6) vs. old masonry (U≈2.5). Condensation occurs when the inner wall drops below the acid or water dew point.

Draft balance

Natural draft vs. required draft pressure — shows from which height enough draft develops.

Flue gas core vs. inner wall

Gas core temperature (dashed) and inner wall temperature (solid) at winter -15 °C — the inner wall reaches the dew point much earlier and decides whether condensation occurs.

Metric comparison

Appliance metrics relative to the average of all appliances using the same fuel (100% = average).

Emissions & ratings

Compliance against the major European emission standards.

EU Ecodesign
compliant
DE BImSchV
stage 2
Austria
compliant
Switzerland
compliant
Denmark
compliant
France (Flamme verte)
7 stars
Italy
4 stars

Certifications

A+EN 13240EcoDesign15a B-VGBImSchV 2. Stufe

Operation & compatibility

Operating modes and approvals declared by the manufacturer.

Continuous burningNo
Multi-flue suitableYes
Room-air independentYes
Central-heating connectionNo
DIBt approvalYes
Typeoptional Raumluftunabhängig
CirculationLuftgeführt
Flue connectionoben, hinten
External combustion air100 mm

Fuels

WoodCoal

Geometry & design

Physical dimensions and outer materials.

Dimensions H×W×D
1570 × 392 × 392 mm
Weight
138 kg
Base shape
eckig
Cladding
Stahl
Colour
schwarz
Efficiency
75 %
Max log length
20 cm
Viewing window H×W
Eckkamin: 2 Scheiben, Eckscheiben
Baking compartment
ohne Backfach

Test certificate

Test report and identification numbers.

Standard
DIN EN 13240
Year
2020
Institute
DBI-Gastechnisches Institut gGmbH Freiberg
Report no.
DBI F 20/09/0786
Article no.
LIVERA-2-L-L-RLU

Data sources: schornstein

Technical parameters
Appliance
Drooff Kaminöfen GmbH & Co. KG Livera 2 L (6 kW)
Manufacturer
Drooff Kaminöfen GmbH & Co. KG
Fuel
Wood
Rated output
6 kW
Exhaust temperature
321 °C
Exhaust mass flow
5.67 g/s
CO₂ content
7 %
Operating pressure
12 Pa (overpressure)
Connection diameter
150 mm
Water dew point (approx.)
55 °C
Acid dew point (approx.)
70 °C