Dovre N.V. Saga 101
Dovre N.V.
Condensation risk
Worst case (old uninsulated masonry chimney, U≈2.5 W/m²K, −10 °C): inner wall drops below dew point 55 °C from approx. 8 m height. A modern insulated stainless-steel chimney avoids this.
Diagrams
Condensation risk
Inner chimney wall temperature over height — modern insulated (U≈0.6) vs. old masonry (U≈2.5). Condensation occurs when the inner wall drops below the acid or water dew point.
Draft balance
Natural draft vs. required draft pressure — shows from which height enough draft develops.
Flue gas core vs. inner wall
Gas core temperature (dashed) and inner wall temperature (solid) at winter -15 °C — the inner wall reaches the dew point much earlier and decides whether condensation occurs.
Metric comparison
Appliance metrics relative to the average of all appliances using the same fuel (100% = average).
Emissions & ratings
Compliance against the major European emission standards.
Certifications
Operation & compatibility
Operating modes and approvals declared by the manufacturer.
Fuels
Geometry & design
Physical dimensions and outer materials.
- Dimensions H×W×D
- 730 × 415 × 580 mm
- Weight
- 100 kg
- Base shape
- eckig
- Cladding
- Gusseisen
- Colour
- schwarz
- Efficiency
- 81 %
- Max log length
- 35 cm
- Viewing window H×W
- Frontkamin: 1 Scheibe, Frontscheibe
- Baking compartment
- ohne Backfach
Test certificate
Test report and identification numbers.
- Standard
- DIN EN 13240
- Year
- 2022
- Institute
- LABORATORY K.V.B.G. - A.R.G.B.
- Report no.
- EZKA/2021-09/00031-2
- Article no.
- 01-90427-000
Data sources: schornstein
Technical parameters
- Appliance
- Dovre N.V. Saga 101
- Manufacturer
- Dovre N.V.
- Fuel
- Wood
- Rated output
- 7.9 kW
- Exhaust temperature
- 274 °C
- Exhaust mass flow
- 6.4 g/s
- CO₂ content
- 7 %
- Operating pressure
- 12 Pa (overpressure)
- Connection diameter
- 125 mm
- Water dew point (approx.)
- 55 °C
- Acid dew point (approx.)
- 70 °C